Specifications for IX81 |
 |
Flexible platform for automated solutions
Complete customisation for individual needs
Independent motorised units
Provided with powerful software |
Back to main page |
Print |
| Microscope body |
Optical system |
UIS2 |
| |
Focus |
Vertical movement: 9 mm stroke with upper limit stopper, coaxial coarse and fine focusing knobs are directly connected to encoder (minimum fine focus graduation: 1 µm, full rotation of fine focusing knobs: 100 µm) |
| |
Primary image port |
Lower branch: Left side port: S1F 100%. Upper branch: Optional right side port or upper back port selectable when built-in magnification changer 1X/1.6X is replaced (2-step light path selection) |
| |
Frontal operation |
Light path selector button, transmitted light intensity control buttons and light ON/OFF switch button, fine/coarse selector button, TTL pulse control (auxiliary) buttons |
| Revolving nosepiece |
|
Sextuple motorised with objective lens retraction in PC mode, simple waterproof mechanism incorporated |
| Transmitted light illuminator |
|
100 W halogen lamp
Illumination pillar tilt mechanism with 30° inclination angle and vibration-reducing mechanism
Condenser holder with 50 mm stroke included, swing-in/out mechanism
Field iris diaphragm adjustable
4 filter holders (ø45 mm, t = 6 mm or less) |
| Observation Tube |
Widefield (FN22) |
Widefield tilting binocular, inclined 35–85°, eyepoint height range: 406 mm–471mm, interpupillary distance adjustable between 50–76 mm, dioptre adjustment function, erect image
Widefield binocular, with centring telescope, inclined 90°, interpupillary distance adjustable 50–76 mm, dioptre adjustment function
Widefield binocular, inclined 90°, interpupillary distance adjustable 50–76 mm, dioptre adjustment function
Widefield trinocular, inclined 30°, 3-step optical path selectable (100:0, 20:80, 0:100), interpupillary distance adjustable 50–76 mm, dioptre adjustment function
|
| Stage |
|
Ceramic-coated coaxial stage with right-hand drive control, 50 mm (X) x 50 mm (Y) stroke, stage insert plate exchangeable (ø 110 mm)
Ceramic-coated coaxial stage with short left handle, 50 mm (X) x 43 mm (Y) stroke, stage insert plate exchangeable (ø 110 mm)
Ceramic-coated plain stage, 232 mm (X) x 240 mm (Y) stage size, stage insert plate exchangeable (ø 110 mm)
Specimen guide to be used with plain stage, 130 mm (X) x 85 mm (Y) stroke
Ceramic-coated narrow plain stage, 160 mm (X) x 240 mm (Y) stage size, stage insert plate exchangeable (ø 110 mm)
Specimen guide to be used with narrow plain stage, 120 mm (X) x 78 mm (Y) stroke
Ceramic-coated upper circular stage, 360° rotatable, 20 mm (X/Y) travel |
| Condenser |
|
Universal, 8 positions for optical devices (5 positions for ø 30 mm, 3 positions for ø 30 mm), aperture iris diaphragm adjustable, with dry front lens NA 0.9/WD 1.5, with oil immersion front lens NA 1.4/WD 0.6
Long universal working distance, 5 positions for optical devices (3 positions for ø 30 mm and 2 positions for ø 38 mm), aperture iris diaphragm adjustable, NA 0.55/WD 27 mm
Long working distance relief contrast, 4 positions for optical devices (for ø 50 mm, relief contrast optical devices rotatable), aperture iris diaphragm adjustable, NA 0.5/WD 45 mm
Ultra long working distance phase contrast, 4 positions for optical devices (for ø 29 mm), aperture iris diaphragm adjustable, NA 0.3/WD 73 mm
DIC, single position for optical device (include 2 optical device holders), 40° injection pipette or electrode insertion angle, aperture iris diaphragm adjustable, with water immersion front lens NA 0.9/WD 3.7 mm, with dry front lens NA 0.9/WD 1.5, with oil immersion front lens NA 1.4/WD 0.6
Motorised universal long working distance, 6 positions for optical devices (3 positions for ø 30 mm and 2 position for ø 38 mm), aperture iris diaphragm adjustable, NA 0.55/WD 27 mm
|
| Reflected light fluorescence unit |
|
L-shaped fluorescence illuminator, exchangeable F.S. and A.S. modules, 2 filter holder sliders (2 positions, ø 32 mm, t = 6 mm or less)
Straight fluorescence illuminator with field iris diaphragm, filter holder slider (2 positions, ø 32 mm, t = 6 mm or less)
Fluorescence cube turret, 6 positions in a rotating turret, built-in shutter
Fast motorised turret, 6 positions, built-in shutter, switching speed ≤300 ms, requires xcellence or cellSens software´
100 W Hg lamp housing and transformer, or 75 W Xe lamp housing and transformer
Motorised turret with 6 positions, built-in shutter |
|
|
|
|
|
|
|
 |
IX81 related Application Report |
|
|
|
|
|