Specifications for IX51 |
 |
Easy, convenient operation
Superb optics
Slim and compact design saves space
Suitable for a large variety of applications |
Back to main page |
Print |
Frame
| Name |
Description |
Article Code |
| IX51S8F-3 |
Manual inverted frame with left-side tilted sextuple nosepiece, field number 22 and light-path prism to left-side image port (80%). For transmitted and reflected illumination. Coarse and fine focussing knobs with maximum focus stroke of 9 mm and 100 µm stroke per full rotation of the fine focus knob. Minimum fine graduation 1 µm. Needs external light power supply. With integrated magnification changer 1.0x and 1.6x. |
N1509200 |
Observation Tubes and Intermediate Tubes
| Name |
Description |
Article Code |
| |
Observation Tubes |
|
| U-BI90-1-2 |
Binocular (Siedentopf) tube with 45° inclination and pupillary distance adjustment from 50 to 76 mm. Adjustable diopter range (± 5 diopter) on right sleeve. To be used with WHN10x/22, WHN10x-H/22 eye-pieces. |
N1510400 |
| U-BI90CT-1-2 |
Binocular (Siedentopf) tube with integrated centring telescope and shutter, 45° inclination and pupillary distance adjustment from 50 to 76 mm. Adjustable diopter range (± 5 diopter) on right sleeve. To be used with WHN10x/22 , WHN10x-H/22 eye-pieces. |
N1510300 |
| U-TBI90 |
Binocular ergo tube with 35° to 85° tilting angle, diopter adjustment on one eyepiece, eyepoint height adjustable from 406mm to 471mm |
035774 |
| U-TR30H-2 |
High eyepoint trinocular tube with 30° inclination and pupillary distance adjustement from 50 to 76 mm. Adjustable diopter range (± 5 diopter) on left sleeve. To be used with WHN10x/22, WHN10x-H/22 eyepieces. Beamsplitter for 3 positions (100/0, 20/80, 0/100). |
N1510500 |
| IX-ATU |
Intermediate tube to use 30° inclined tube on IX frame |
037230 |
| U-MO |
Monocular tube, two separated items incl. one WH10x eyepiece, can be also used to adapt BX2 photo- or TV systems |
035775 |
| |
|
|
| |
Eyepieces |
|
| WHN10X-1-2 |
Widefield eyepiece, FN22 |
N2682200 |
| WHN10X-H-1-2 |
Widefield eyepiece, focusable, FN22 |
N2682300 |
| |
|
|
| |
Intermediate Tubes |
|
| GX-SPU-1-2 |
Intermediate attachment tube with side port, dovetail mount to use with GX51 (not for GX71) to combine with the BX-TV adapter U-TV0.5xC, U-TV0.35xC and U-TV1x, not to use with other TV adapter combinations |
N2193100 |
| U-KPA |
Intermediate tube to accept tint plates, compensators and analyser |
037220 |
| U-EPA2 |
Eyepoint adjuster, 30mm high, rectangular shape |
037223 |
| U-CA |
Magnification changer 1x/1.25x/1.6x/2x |
037205 |
| U-ECA |
Magnification changer 1x/2x |
037222 |
Objectives
The full range of objectives can be found under Objectives & Accessories. For the optimal choice of objectives according to your application please Contact Us.
Stages
| Name |
Description |
Article Code |
| IX2-SP |
Plain stage (232x240mm) with metal centerplate (outer ø 110mm, inner ø 25mm) |
035753 |
| IX2-KSP |
Narrow plain stage (160x240mm) with metal centerplate (outer ø 110mm, inner ø 25mm) |
035752 |
| IX2-SFR |
Mechanical stage (260x201mm) with right-hand, flexible low drive control |
035754 |
| IX-SVL2 |
Mechanical stage (260mm x 201mm) with left-hand tension adjustable coaxial X-Y control, traverse: 50mm x 43mm, for BX51/61WI: WI-FSH (38181) required |
038182 |
| IX2-GS |
Gliding stage with detachable rubber surface and 6 M6 holes to adapt manipulators, traveling range +/- 10mm, including metal insert plate and two stage clips |
035773 |
| IX2-NPS |
Nosepiece stage with minimised focus drift for time lapse applications. Focusing possible, body, insert plate and 4x20mm spacers included . |
N1170082 |
| |
|
|
| |
Stage Accessories |
|
| IX-SUSP |
Stainless stage plate for micromanipulators |
037392 |
| IX-SCL |
Slide clips (1 pair) |
037388 |
| IX-CP50 |
Stage insert plate for IX and CK40 stages, inner diameter 50mm |
037397 |
| CK2-SS |
Stage extension plate for CK40/30, CK-2, IX |
030362 |
| |
|
|
| |
Specimen Guides and Accessories |
|
| IX-MVR |
Attachable specimen guide (130x85mm) with flexible right-hand vertical low drive control, magnetic labels for microtiter plate 6x12, to use with IX-SP |
037395 |
| CK40-MVR |
Attachable specimen guide, right-hand low driven coaxial stage control, movement range: x=120mm, y=78mm, with 3 inserts: 1) for slides and Petri dishes 54mm ø, 2) for microtiter plates (60 or 72) & Petri dishes 65mm ø, 3) plate 80x55mm for Petri dishes 30 |
031358 |
| IX-HOP |
Holder for Petri dishes (65/54/35mm ø) |
037400 |
| IX-HOS |
Slide glass holder for 76x26mm slides and Petri dishes (54mm ø) |
037399 |
| IX-HOT |
Microtiter plate holder (60 or 72 well), replaceable coordinate scales, Petri dish holder (65mm ø) |
037398 |
| IX-CLMT |
Click stop for IX-MVR |
037377 |
| IX-CLM96 |
Click stop for 96 microtiter plate for IX-MVR |
037378 |
| IX-PPM |
Millimeter graduation indicator for IX-MVR |
037379 | <
Illumination Pillars, Lamphouses and Power Supplies
| Name |
Description |
Article Code |
| |
Illumination Pillars |
|
| IX2-ILL30-1-5 |
Illumination pillar for precentered 30W Halogen, 1 filter holder for filter (diameter: 45mm, thickness: 11mm), fixed F.S. and fixed condenser (NA 0.3, WD 72mm) to use with IX-SL and IX2-SLP slider |
N2663700 |
| IX-ILL100-1-5 |
30° tiltable illumination pillar for centerable 100W Halogen lamp housing, 4 turnable filter holders, F.S. and 360° turnable condenser support |
N2663500 |
| IX2-ILL100-1-5 |
Tiltable illumination pillar for centerable 100W Halogen lamp housing, 4 filter holders, F.S. and condenser support |
N2663800 |
| |
|
|
| |
Lamphouses |
|
| U-LS30-3-5 |
30W Halogen lamphouse, to mount on IX50, IX51, CK40(M), BX-KMA, CKX31/41 |
N2192300 |
| U-LH100-3-5 |
Halogen lamphouse, incl. connecting cord |
N2211900 |
| U-LH100L-3-5 |
100W Halogen lamphouse with collector lens and long connecting cable |
N2212100 |
| IX-HLSH100 |
Centerable 100W Halogen lamphouse |
037920 |
| |
|
|
| |
Power Supplies |
|
| TL-4-5 |
Power supply for 30 W halogen lamp. |
N2188200 |
| TH-4-200-1-5 |
Transformer for 100W Halogen lamp, 220-240V |
N2659600 |
| TH4-HS-1-5 |
Optional hand switch for TH-4, cable length 2m |
N2659400 |
| |
|
|
| |
Bulbs |
|
| AHS-LAMP 12V/100W |
Halogen bulb (AHS-LAMP), precentered, 12V/100W |
035359 |
| 6V30W |
6V30W Halogen Bulb |
E0430150 |
Condensers
| Name |
Description |
Article Code |
| IX2-MLWCD |
Universal long working distance condenser, NA 0.5, WD=45mm, 4-hole turret for optical elements, aperture stop including 3 RC elements (RC1, RC2 and RC3) and polariser for Relief Contrast = RC |
035771 |
| IX2-LWUCD |
Universal long working distance condenser, NA 0.55, WD=27.0mm, 5-hole turret for optical elements, aperture stop |
035767 |
| IX2-ULWUCD |
Ultra-long working distance condenser, NA 0.3, WD=73mm, A.S., 4-hole turret equipped with two phase annular stops PHLU and PH2U |
037740 |
| IX2-DICD |
High numerical DIC condenser with exchangeable toplens and polariser, for single DIC element only |
035769 |
| IX-ADUCD |
Adapter to use U-UCDB on IX with optic and fine adjustment |
037788 |
| U-UCD8-2 |
Universal achromatic/aplanatic condenser with 5 positions for big and 3 positions for small optical elements, WD=1.5 mm, swing-out arm for top lens, aperture diaphragm, 360° rotatable polariser, additional front indicators for use with BXWI, needs top lens |
N1182582 |
Fluorescence Equipment
| Name |
Description |
Article Code |
| |
Illuminators and Turret |
|
| IX2-RFA |
Straight fluorescence condenser with centerable fieldstop and filter slider |
035763 |
| IX2-RFAL |
L-shaped fluorescence condenser, with centerable aperture stop, field stop and filter slider |
035764 |
| IX2-RFAC |
Fluorescence cube cassette, 6 positions on turret and manual shutter |
035765 |
| |
|
|
| |
Illuminator Accessories |
|
| IX2-RFSPOT |
Pinhole adapter for IX2-RFAL only, use 16mm pinhole (ex. Melles Griot), pinhole focusing, centering and in/out function |
N1169082 |
| U-RFSS |
Rectangular field stop adapter for IX2-RFAL only, up to 2/3" CCD camera field with U-TV1x, field stop in/out function |
N1207600 |
| IX2-SL5 |
5 position filter slider including shutter plates, 32mm ND and 25mm FL filter applicable, for IX2-RFA, IX2-RFAL, IX2-RFAEVA-2 |
N1208000 |
| 32ND50 |
Neutral density filter (50% transmission) |
037823 |
| 32ND25 |
Neutral density filter (25% transmission) |
037824 |
| 32ND12 |
Neutral density filter (12% transmission) |
037825 |
| 32ND6 |
Neutral density filter (6% transmission) |
037826 |
| |
|
|
| |
Lamphouses |
|
| U-LH100HG |
Lamphouse incl. lamp socket and aspherical collector lens for 100W mercury lamp |
037940 |
| U-LH100HGAPO-1-5 |
Lamphouse incl. lamp socket and aspherical, apochromatic corrected collector lens for 100W mercury discharge lamp |
N2666400 |
| U-LH75XEAPO |
Lamphouse incl. lamp socket and aspherical, apochromatic corrected collector lens for 75W Xenon burner |
037944 |
| U-LH50HG-1-5 |
Lamphouse for 50W mercury discharge lamp |
N2663900 |
| U-CLA |
Collector lens and lamp socket adjustment tool |
037972 |
| |
|
|
| |
Power Supplies |
|
| U-RFL-T |
Power supply for 100W mercury discharge lamp |
N2251000 |
| U-RX-T |
Power supply for 75W xenon discharge lamp |
N2251100 |
| U-RFLT50 |
Power supply for 50W mercury lamp, 220-240 V |
037949 |
| |
|
|
| |
Burner |
|
| USH-103OL |
USHIO 100W mercury burner |
N1217800 |
| L2194-01 75W-XBO |
Super-quiet 75W Xenon-burner with guaranteed lifetime of 1.000 hours, average lifetime 2.000 hours. |
035375 |
| 50W/AC/L2 |
HBO Burner 50W mercury |
035403 |
| |
|
|
| |
Fluorescence Filter |
|
| |
The full range of fluorescence filters can be found under Objectives & Accessories. For the optimal choice of fluorescence filters according to your application please Contact Us. |
|
| |
|
|
| |
Fiber Guide Adaptation |
|
| LG-ULHAD |
Light guide adapter for U-ULH lamphouse with brightness control shutter, incl. centering target |
033742 |
| U-RLGAD |
Adapter for reflected light illumination with fiberguide |
037956 |
| FV5-FL-R |
Reflected light illumination unit with fiberguide |
038493 |
Motorised Equipment
| Name |
Description |
Article Code |
| IX2-UCB-2 |
Control box for the motorised units, equipped with power source for U-LH100L-3, incl. IX2-BSW basis software |
N1169600 |
| U-HSTR-2-5 |
Hand switch for the control of the illuminator turret and shutter, condenser wheel, top lens (BX2) and aperture stop (BX2) and the nosepiece. Customised settings possible. Can only be used together with the BX-UCB and IX2-UCB control boxes |
N2664600 |
| BX-UCBRS232 |
Special RS232 cable (with socket/socket) of 1.8m length for connecting the control box with the PC |
039638 |
| UCBRS232 |
Special RS232 cable (socket/socket) of 3m length for connecting the control box with the PC |
E0430032 |
| IX2-RFACA-1-5 |
Motorised six position fluorescence cube cassette, manual shutter |
N2665900 |
| IX2-LWUCDA-2-5 |
Motorised long working distance condenser, NA0.55, WD=27.0mm, 6-position turret for optical elements (3 big and 3 small ones), manual aperture stop |
N2663000 |
| U-FWR-1-5 |
Filterwheel for reflected illumination with 6 positions, switching time to neighboured positions 0.6s, holds filter of 32 and 25mm diameter |
N2665600 |
| U-FWO |
Filterwheel for observation with 6 positions, switching time to neighboured positions 0.6s, holds filter of 32 and 25mm diameter |
037240 |
| IX2-IFSHA-1-5 |
Shutter interface for two IX2-SHA shutter on IX71/51 (IX2-UCB control box necessary!) |
N2666200 |
| IX2-SHA-1-5 |
Motorised shutter for reflected and transmitted light (0.4sec switching time) |
N2666100 |
| |
Different motorised stages are available. Please Contact Us for further information. |
|
Heating plates and Incubators
| Name |
Description |
Article Code |
| |
Heating Plates for Specimen Guides |
|
|
For detailed informations regarding heating plates for specimen guides please Contact Us. |
|
| |
|
|
| |
Stage Insert Plates |
|
|
For detailed informations regarding stage insert plates please Contact Us. |
|
| |
|
|
| |
Stage Incubators |
|
|
For detailed informations regarding stage incubators please Contact Us. |
|
|
|
|