Specifications for CKX41 |
 |
Large variety of applications
Enhanced image clarity
Outstanding flat images
Cost-effective |
Back to main page |
Print |
Frame
| Name |
Description |
Article Code |
| CKX41SF-5 |
Microscope frame for UIS2 optics with fixed binocular tube FN20, incl. 2 eyepieces WHB10x, integrated quadruple revolving nosepiece, plain stage (160x250mm), coarse and fine focusing with tension adjustment mechanism, illuminator pillar with lamphouse and long working distance condenser NA 0.3, WD=72mm, aperture stop, allen key AQ2302, transformer integrated in frame, incl. Lamp socket and two halogen bulbs (30W) |
N2187100 |
| |
|
|
| |
Halogen Bulb |
|
| 6V30W |
6V30W halogen bulb |
E0430150 |
Observation Tubes and Documentation Tubes
| Name |
Description |
Article Code |
| |
Tubes |
|
| U-CBI30-2-2 |
Binocular tube with leadfree optics, 30° inclination and pupillary distance adjustment from 48-75 mm. Adjustable diopter range (± 5 diopter) on left sleeve. For WHB10x, WHB10x-H eyepieces with field-number 20. |
N1468300 |
| U-TBI-3 |
Tilting binocular tube, inclination 5-35°, interpupillary distance adjustment 48-75mm, with diopter adjustment on left sleeve |
037121 |
| U-CTR30-2-2 |
Trinocular tube with leadfree optics, 30° inclination and pupillary distance adjustment from 48-75 mm. With fixed 50/50 light distribution and adjustable diopter range (± 5 diopter) on left sleeve. For WHB10x, WHB10x-H eyepieces with field-number 20. |
N1468400 |
| U-BI30-2-2 |
Binocular tube inclined 30°, with diopter adjustment on left sleeve, FN22 |
N1468700 |
| CKX-TBI |
Tilting binocular tube for CKX41 with FN20, variable inclined angle is 30°-60°, interpupillary distance between 50-76mm, diopter adjustment by helicoid on right side sleeve, 2 eyepieces for FN 20 are included |
N1182600 |
| U-TR30-2-2 |
Trinocular tube with 30° inclination and pupillary distance adjustment from 50 to 76 mm. Adjustable diopter range (± 5 diopter) on left sleeve. To be used with WHN10x/22 , WHN10x-H/22 eyepieces. Beamsplitter for 3 positions (100/0, 20/80, 0/100). |
N1512000 |
| |
|
|
| |
Eyepieces |
|
| WHB10x-2 |
Widefield eyepiece for U-CBI30-2-2 and U-CTR30-2-2, FN20 |
N1129900 |
| WHB10xH-2 |
Widefield eyepiece, focusable, for U-CTR30-2-2 |
N1130000 |
| WHN10X-1-2 |
Widefield eyepiece, FN22 |
N2682200 |
| WHN10x-H-1-2 |
Widefield eyepiece, focusable, FN22 |
N2682300 |
| |
|
|
| |
Centering Telescopes |
|
| CT-5 |
Centering telescope for phase contrast, diameter 23.5mm |
031194 |
| U-CT30 |
Centering telescope for phase contrast, diameter 30mm |
037091 |
Stage Accessories
| Name |
Description |
Article Code |
| CK40-MVR |
Attachable specimen guide, right-hand low driven coaxial stage control, movement range: x=120mm, y=78mm, with 3 inserts: 1) for slides and Petri dishes 54mm ø, 2) for microtiter plates (60 or 72) & Petri dishes 65mm ø, 3) plate 80x55mm for Petri dishes 30mm ø |
031538 |
| CK2-SS |
Stage extension plate for CK40/30, CK-2, IX |
030362 |
| CK40-CPG |
Glass stage insert for CK40 and IX stages, can be used from 4x to 20x magnification |
031540 |
Heating Plate
| Name |
Description |
Article Code |
| MATS-U55R30 |
Heatable glass insert plate with controller. Temperature range: room temperature to 50°C, precision: ±0.3°C. To be used with up to 40x long working distance objectives |
039632 |
Contrast Slider
| Name |
Description |
Article Code |
| |
Phase Contrast (Precentered, Common Phase Ring 10x - 40x), needs PHP Objectives |
|
| IX2-SLP |
"Centering free" phase contrast slider with 3 positions, equipped with IX2-PHL and common phase annular stop (10x, 20x and 40x) and BF postion, to use with PHP objectives |
N1140300 |
| |
|
|
| |
Phase Contrast (Centerable), needs PH Objectives |
|
| IX2-SL |
Centrable phase contrast slider with 3 positions, equipped with IX2-PHL phase annular stop, two empty positions |
035793 |
| IX2-SLPHC |
PHC Phase annular stop for center slider position and for CPL10xPH, CPLFL10xPH, LCACH20xPH, for IX2-SL condenser slider |
035794 |
| IX2-SLPH1 |
PH1 Phase annular stop for center position of IX2-SL condenser |
N1140100 |
| IX2-SLPH2 |
PH2 Phase annular stop for right position of IX2-SL condenser |
035795 |
| CT-5 |
Centering telescope for phase contrast, diameter 23.5mm |
031194 |
| |
Note: Alternative use of IX2-SLPHC or IX2-SLPH1 corresponding to used objectives. |
|
| |
|
|
| |
Relief Contrast |
|
| CKX-RCD |
RC condenser NA 0.45, WD 45mm for CKX41 and CKX31, including two position slider for RC modulators (10x and common for 20x/40x); if one position is not used by modulator BF can be performed |
N1157782 |
| CT-5 |
Centering telescope for phase contrast, diameter 23.5mm |
031194 |
Objectives
| Name |
Description |
Article Code |
| |
Brightfield Plan Achromat Objectives |
|
| PLCN4x/0.1 |
C Plan Achromat 4x with 18.5 mm working distance and numerical aperture (NA) of 0.1 . |
N1216600 |
| PLCN10x/0.25 |
C Plan Achromat 10x with 10.5 mm working distance and numerical aperture (NA) of 0.25. |
N1216700 |
| PLCN20x/0.40 |
C Plan Achromat 20x with 1.2 mm working distance and numerical aperture (NA) of 0.40. Cover correction = 0.17 . |
N1216800 |
| PLN2x/0.06 |
Plan Achromat 2x with 5.8 mm working distance and numerical aperture (NA) of 0.06. |
N1215600 |
| |
PHP Phase Contrast Objectives |
|
| UPLFLN4xPHP/0.13 |
U Plan Fluorite Phase 4x with 16.4 mm working distance, numerical aperture (NA) 0.13 . For IX2-PHL ring in IX2-SLP |
N1507400 |
| CACHN10xPHP |
Achromat Phase 10x with 8.8 mm working distance, numerical aperture (NA) 0.25 . For common phase ring in IX2-SLP |
N1507300 |
| LCACHN20xPHP/0.40 |
Long working distance Achromat Phase 20x with 3.2 mm working distance, numerical aperture (NA) 0.40 and cover correction = 1. For common phase ring in IX2-SLP. |
N1477800 |
| LCACHN40xPHP/0.55 |
Long working distance Achromat Phase 40x with 2.2 mm working distance, numerical aperture (NA) 0.55 and cover correction = 1. For common phase ring in IX2-SLP. |
N1477900 |
| |
|
|
| |
PH Phase Contrast Objectives |
|
| UPLFLN4xPH/0.13 |
U Plan Fluorite Phase 4x with 17 mm working distance, numerical aperture (NA) 0,13 . For IX2-PHL phase annular stop. |
N1479100 |
| CPLN10xPH/0.25 |
Plan Achromat Phase 10x with 10 mm working distance and numerical aperture (NA) of 0.25. To be used with PHC phase annular stop. |
N1507800 |
| LCACHN20xPH/0.4 |
Long working distance Achromat Phase 20x with 3.2 mm working distance, numerical aperture (NA) 0.40 and cover correction = 1mm. To be used with PHC phase annular stop. |
N1477600 |
| LCACHN40x2PH/0.55 |
Long working distance Achromat Phase 40x with 2.2 mm working distance, numerical aperture (NA) 0.55 and cover correction = 1mm. To be used with PH2 phase annular stop. |
N1477700 |
| |
|
|
| |
Relief Contrast Objectives |
|
| CPLN10xRC/0.25 |
Plan Achromat Relief Contrast 10x with 9.7 mm workingdistance, numerical aperture (NA) 0.25 . |
N1507900 |
| LCACHN20xRC/0.40 |
Long working distance Achromat Relief Contrast 20x with 2.8 mm working distance, numerical aperture (NA) 0.40 and cover correction = 1.5 mm. |
N1478000 |
| LCACHN40xRC/0.55 |
Long working distance Achromat Relief Contrast 40x with 1.9 mm working distance, numerical aperture (NA) 0.55 and cover correction = 1.5 mm. |
N1478100 |
| |
|
|
| |
This selection focuses on the objectives most used with CKX41. The full range of objectives can be found under Objectives & Accessories. |
|
Fluorescence Equipment
| Name |
Description |
Article Code |
| |
Illumination |
|
| CKX-RFA |
Fluorescence condenser for CKX41 with FS, shutter and filter pocket (diameter = 32mm); including a three position slider (one for BF, blue (WB) and green (SWG) fluorescence) |
N1157882 |
| U-RFLT50 |
Power supply for 50W HBO |
037949 |
| U-LH50HG-1-5 |
Lamphouse for 50W mercury discharge lamp |
N2663900 |
| 50W/AC/L2 |
HBO Burner 50W mercury |
035403 |
| |
|
|
| |
Fluorescence Filter |
|
| CKX-NU |
UV Filterset for CKX-RFA consist out of excitation filter (330-385nm), barrier filter (420nm) and dichroic mirror (400nm). Needs a small Philips screw driver for installation into the condenser and the UV cut filter must be removed from 50W mercury lamp |
N1157600 |
| |
|
|
| |
Other filtersets are available on request. Please Contact Us for further information. |
|
Filter
| Name |
Description |
Article Code |
| |
Filter for Transmitted Light |
|
| 45LBD-2 |
Colour temperature compensation filter, 45mm ø |
035126 |
| 43ND-25W45 |
Neutral density filter |
035137 |
| 43IF-550-W45 |
Interference filter |
035159 |
| 45KB-4-L |
Daylight filter 45mm ø |
035167 |
| |
|
|
| |
Filter for Reflected Light Fluorescence |
|
| 32ND6 |
Neutral density filter (6% transmission) |
037826 |
| 32ND12 |
Neutral density filter (12% transmission) |
037825 |
| 32ND25 |
Neutral density filter (25% transmission) |
037824 |
| 32ND50 |
Neutral density filter (50% transmission) |
037823 |
Cameras
| DP20-Kit |
2 Mpx, 1/1.8 inch , colour CCD camera with control box for standalone use (no PC required). Operation via on-screen menue. Image storage on Compact Flash card. Dynamic range 10 bit. PC interface USB2.0. Incl. 1GB CF Card. The DP20 features fast live image with 15fps in full resolution (1600x1200), superb color quality and an easy to use switchpanel interface for control and acquisition without using a PC. The on-screen software offers calibration and measurement functions as well as storage options. Images will be stored on a compact flash card and can be transferred to a PC via the included data transfer software. Image formats: 1600x1200; 1280x960.
The DP20-Kit contains: camera head, control box, transfer software, 1GB Compact Flash Card. Additionally required is a commercially available UXGA (1600x1200 pixel) monitor to be connected directly to the control box. Optional available is the control using the cell*-family and analysis software packages. |
E0430668 |
| U-TV1x-2 |
Direct image video adapter tube 1x. |
037175 |
| U-CMAD3 |
C-mount adapter ring. |
037194 |
|
|
|